Fraser Rise Building
Inspections
★★★★★ 4.8 on Google · 570+ reviews

Pre-handover (PCI) inspection in Fraser Rise

The finished house inspected room by room, roof by drone, while your final payment is still held.

  • House finished and cleaned, two to three weeks out from settlement
  • 2 to 3 hours on site
  • Report within 24 hours
Request a quoteA few details and one of our inspectors rings you back.

No obligation. We use your details for your quote and may contact you about it even if you don't finish.

Fully licensed & accredited

Stage7 of 7
When to bookHouse finished and cleaned, two to three weeks out from settlement
Time on site2 to 3 hours on site
Inspected againstThe VBA Guide to Standards and Tolerances 2015, the NCC, your contract drawings and inclusions

What is included in a Fraser Rise pre-handover (PCI) inspection

  • Every room: paint, plaster, cornices, doors, windows and floors
  • Wall and ceiling finish in natural light
  • Wet areas: tiling, grout, silicone, screens and drainage
  • Kitchen and laundry: cabinetry, benchtops and appliances installed
  • External: render, brickwork, cladding, caulking and paint
  • Roof, gutters, downpipes and stormwater connection
  • Roof space where safely accessible
  • Garage door, slab falls and driveway
  • Paths, porch, alfresco and step compliance
  • Site drainage, ponding and slab edge exposure
  • Fencing, gates, letterbox and clothesline where in contract
  • Contract inclusions and selections against what was built
  • Compliance certificates available for waterproofing, termite and glazing
  • A numbered, photographed defect list for the site supervisor
Why it matters here

Pre-handover (PCI) inspections on Fraser Rise builds

This is the inspection Fraser Rise books more than any other. The homes are large, the roofs are broken up by parapets and box gutters, and the list tends to be about water. Exhaust fans blowing into the roof space instead of outside. Box gutter overflows placed where roof water can pour straight into them. Parapet capping laid flat when it must fall at least 5 degrees. Upstairs showers leaking at the corners, and no waterstop under the screen. Add cracked tiles and broken underlaps seen from the drone and the case for a reinspection before settlement is usually made.

What we find at this stage in Fraser Rise

  • Exhaust fans not ducted to outside air
  • Box gutter overflow that does not comply
  • Parapet capping without the required fall
  • Shower leaking at the corners
  • No waterstop under the shower screen
Insufficient slope on parapet capping, recorded on a pre-handover inspection in Fraser Rise
Parapet capping laid flat instead of falling at least 5 degrees
Sample findings

Sample defects found during our pre-handover (PCI) inspections in Fraser Rise

Annotated findings from Pre-handover (PCI) inspections.

Exhaust fan not ducted externally, recorded on a pre-handover inspection in Fraser Rise
Exhaust fan duct ending in the roof space instead of outside
Non-compliant box gutter overflow, recorded on a pre-handover inspection in Fraser Rise
Box gutter overflow placed where roof water runs straight into it
Shower leak at the corners, recorded on a pre-handover inspection in Fraser Rise
Moisture at a shower corner showing the recess is leaking
No waterstop installed under a shower screen, recorded on a pre-handover inspection in Fraser Rise
No waterstop under the shower screen to keep water in the recess

The other stages of a Fraser Rise build

  1. Bored piers inspection in Fraser Rise1Bored piersHoles drilled and steel cages in, with the concrete pump not yet booked
  2. Slab pre-pour inspection in Fraser Rise2Slab pre-pourFormwork, pods, barrier and steel finished, a day ahead of the concrete truck
  3. Frame inspection in Fraser Rise3FrameWalls standing, trusses fixed and roof covering on, before insulation goes in
  4. Lock-up (pre-plaster) inspection in Fraser Rise4Lock-up (pre-plaster)Windows, external doors and cladding done, services roughed in, plaster not started
  5. Fixing inspection in Fraser Rise5FixingDoors, architraves, skirtings and cabinets in, painter yet to start
  6. Waterproofing inspection in Fraser Rise6WaterproofingMembrane on and cured in every wet area, tiler not yet on site

All construction stage inspections in Fraser Rise →

Guides

Construction stage guides for Fraser Rise

All guides →

Book a pre-handover (pci) inspection in Fraser Rise

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Pre-handover (PCI) inspections in Fraser Rise: common questions

Why does a fan ducted into the roof space matter?

It pumps warm, wet air into the roof where it condenses on cold surfaces, soaks insulation and can lead to mould on the ceiling. The NCC and most plans need it taken to outside air.

What makes a box gutter overflow non compliant?

It has to carry water away safely when the outlet blocks, without letting roof water run straight in. AS 3500.3 sets the acceptable designs, and the ones we flag do not follow them.

How do you find a shower leak at handover?

We run the shower and use a moisture meter and thermal camera on the walls and on the ceiling below. Corners and screen channels are where leaks show first.

Can I attend the inspection?

Yes, and it helps. You see each item where it is, which makes the handover meeting easier.

Do you come back after the fixes?

Yes. The reinspection marks every item as fixed, partly fixed or still open, with photos.

What if the builder refuses one of the items?

Each item cites the clause or tolerance it fails. If that does not settle it, the Victorian path is the Building and Plumbing Commission's dispute resolution service and then VCAT.

CallGet a Free Quote